[. . . ] Gas Dryer
PRODUCT MODEL NUMBERS WGD4800B, WGD4810B, WGD4850B, WGD4890B, WGD5500B, WGD5800B, WGD5810B, WGD4870B, WGD5000D, WGD4810E, WGD4815E, WGD4915E, WGD4975E, WGD4616F, WGD4916F
29" Wide Models Dryer Dimensions
29" (737 mm)
29" (737 mm)
27" Wide Models Dryer Dimensions
27" (686 mm)
433/8" (1102 mm)
433/8" (1102 mm)
43" (1092 mm)
1/2" (13 mm)
11/2" (38 mm)
11/2" (38 mm)
133/4" (349 mm)
NOTE: Leveling legs should be 1/2" (13 mm) (to match height of 3. 6 cu. [. . . ] Louvered doors with equivalent ventilation openings are acceptable.
■■ Companion appliance spacing should also be considered.
INSTALLATION REQUIREMENTS
GAS SUPPLY REQUIREMENTS
Gas supply: This dryer is equipped for use with Natural gas. When acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6. 1 m). An individual manual shutoff valve must be installed within 6 ft (1. 8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223. 1.
ELECTRICAL REQUIREMENTS
A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit are recommended.
VENTING REQUIREMENTS
Exhaust venting: Exhaust your dryer to the outside. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.
Determine vent length and elbows needed for best drying performance:
■■ Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
Exhaust hoods: Recommended Styles:
NOTE: Do not use vent runs longer than those specified in Vent System Chart. Exhaust systems longer than those specified will:
■■ Shorten life of dryer. [. . . ] For complete details, see Installation Instructions packed with product. [. . . ]